Heat Pumps in 2027: A Sound Investment or Huge Bills? Calculations for 80–150 m² Homes

Heat Pumps in 2027: A Sound Investment or Huge Bills? Calculations for 80–150 m² Homes

Rating
—/5 0 ratings
Follow us on Google News
Home & Design16 min read

Heat pumps enter 2027 in a market where technical efficiency does not automatically translate into lower bills. In Romania, the gap between electricity and natural-gas prices can wipe out the advantage of high-performance equipment, particularly if the system must produce very hot water for radiators. In an insulated home with low flow temperatures, no gas connection, or intelligently used solar generation, however, the calculation can look entirely different.

The context is current: on 26 November 2026, the Ministry of Energy put forward a mechanism for supplying household gas from April 2027, with an estimated average final price of about 0.27666 lei/kWh, but no guaranteed final price cap. New European restrictions on placing certain categories of equipment using fluorinated refrigerants on the market will also take effect on 1 January 2027. In this analysis, InfoBuz compares nine home scenarios, measured data from real installations, the cost of a freezing day and investment over 10–15 years.

Heat pumps in 2027: why the market is growing but profitability remains local

According to data published by the European Heat Pump Association on 28 September 2026, around 1.163 million residential heat pumps were sold in the first half of the year across the 12 European countries analysed, compared with 1.048 million in the equivalent period of 2025 — an increase of 11%. Romania is not included in that sample, so the figures do not demonstrate the same sales trend in the Romanian market.

A heat pump transfers energy from the outdoor environment into a home. Its electricity consumption can be much lower than the thermal energy it supplies, but costs depend on energy tariffs, outdoor temperatures and the design of the internal distribution system. The International Energy Agency’s study of poorly insulated buildings shows that energy savings can still be possible in such homes. Financial savings, by contrast, depend heavily on the ratio between gas and electricity prices. Insulation simultaneously reduces the energy required and the capacity of the equipment needed.

What real-world measurements show: catalogue SCOP versus system efficiency

In the WP-QS im Bestand project, Germany’s Fraunhofer ISE monitored installations in existing buildings. During the main assessment year, 2024, the 49 air-source heat pumps recorded seasonal performance factors (SPF) between 2.6 and 4.9, with an average of 3.4. The 13 ground-source systems assessed in the same period recorded values between 3.6 and 5.4. The final press release of 3 November 2025 states that 77 systems were monitored over the project’s full duration. The sample is not representative of all Romanian homes, but it demonstrates how widely real-world results can vary.

COP expresses the ratio of heat supplied to electricity consumed at a given operating point. SCOP is the standardised seasonal indicator in product documentation. Measured in operation, SPF depends on the boundaries of the measurement system, climate, hot water, auxiliary pumps and electric resistance heaters. A catalogue SCOP of 4.8 does not mean the actual bill can always be calculated by dividing heat demand by 4.8. In InfoBuz simulations, SPF is used for the heating system, including relevant auxiliary consumption and any backup electric contribution, but excluding domestic hot water.

At what temperature does a heat pump become more expensive? A documented technical example

In technical data sheets, A−7/W35 means outdoor air at −7°C and flow water at 35°C. Comparisons must use the same conditions and the same model. To illustrate the effect of temperature without making promotional claims, we use an example from the technical documentation for the Panasonic Aquarea T-CAP H monobloc, the 9 kW single-phase WH-MXC09H6E5 model. It is a model from an earlier generation, used solely as a technical example, not as a purchase recommendation for 2027.

Outdoor air temperature COP at 35°C flow temperature COP at 55°C flow temperature Cost of 100 kWh of heat at 35°C Cost at 55°C
+7°C 4.84 2.94 24.79 lei 40.82 lei
+2°C 3.59 2.21 33.43 lei 54.30 lei
−7°C 2.85 2.02 42.11 lei 59.41 lei
Source for COP: manufacturer’s technical data sheet; costs are InfoBuz calculations at 1.20 lei/kWh of electricity. These are test points, not results measured by InfoBuz or daily averages.

At −7°C, moving from 35°C to 55°C increases electricity use for the same amount of heat by around 41%. In the documentation for the same model, the SCOP for an average climate is 4.60 at 35°C and 3.33 at 55°C. Newer models may produce different results: the purchasing criterion should be the data sheet for the equipment actually offered. See also the European Commission’s explanation of labelling for 35°C and 55°C applications.

During winter, defrosting the outdoor unit can temporarily interrupt heat supply and consume energy. Air humidity, not just temperature, affects the frequency of the cycles. Thermal capacity at the design outdoor temperature must be checked before sizing; the minimum operating temperature cited in advertising does not prove that the equipment can deliver sufficient capacity at that point.

80, 120 or 150 m² homes: how much do they really consume?

Floor area alone does not determine the capacity required. A professional heat-loss calculation considers the building envelope, air infiltration, windows, ventilation, design temperatures and the demand of each room. For comparison, we use three illustrative profiles, not official energy classes: good insulation (50 kWh of heat/m²/year, peak load of 35 W/m², SPF 4); average insulation (100 kWh/m²/year, 60 W/m², SPF 3.4); and poor insulation (160 kWh/m²/year, 100 W/m², SPF 2.6). The different SPF values also assume different distribution and operating conditions; they are not determined by insulation alone.

The assumed final prices are 1.20 lei/kWh for electricity and 0.30 lei/kWh for gas, with a seasonal efficiency of 92% for the condensing boiler, on the same energy basis as billed gas. These are not guaranteed tariffs for 2027. For electricity, the reference is Hidroelectrica’s November offer, previously analysed in InfoBuz’s guide to electricity bills. For gas, the 28 November roundup of offers shows, for example, offers around 0.30 lei/kWh for Bucharest. Check the network operator, contract and the price actually billed.

Area / profile Hypothetical peak load Annual heat demand Heat-pump electricity use Heat-pump cost/year Gas cost/year
80 m² / good 2.8 kW 4,000 kWh 1,000 kWh 1,200 lei 1,304 lei
80 m² / average 4.8 kW 8,000 kWh 2,353 kWh 2,824 lei 2,609 lei
80 m² / poor 8 kW 12,800 kWh 4,923 kWh 5,908 lei 4,174 lei
120 m² / good 4.2 kW 6,000 kWh 1,500 kWh 1,800 lei 1,957 lei
120 m² / average 7.2 kW 12,000 kWh 3,529 kWh 4,235 lei 3,913 lei
120 m² / poor 12 kW 19,200 kWh 7,385 kWh 8,862 lei 6,261 lei
150 m² / good 5.25 kW 7,500 kWh 1,875 kWh 2,250 lei 2,446 lei
150 m² / average 9 kW 15,000 kWh 4,412 kWh 5,294 lei 4,891 lei
150 m² / poor 15 kW 24,000 kWh 9,231 kWh 11,077 lei 7,826 lei
InfoBuz model. Space heating only, excluding hot water, cooling, fixed charges and maintenance. Peak capacity and annual demand are independent budgeting assumptions, not a sizing calculation for specific equipment. Amounts were calculated before consumption figures were rounded.

For a 120 m² home, the difference between the poor and good profiles can exceed 7,000 lei a year for the heat pump. This shows why upgrading the building envelope and heat emitters may warrant assessment before choosing equipment. Replacing a few radiators can reduce the required flow temperature, but the result needs to be checked room by room. See also InfoBuz’s analysis of underfloor heating versus radiators.

The break-even point against gas: the decisive formula for 2027

The cost of one useful kWh of heat is the electricity price divided by SPF for the heat pump, and the gas price divided by boiler efficiency for gas. The SPF break-even point is therefore calculated as the electricity price multiplied by boiler efficiency, divided by the gas price. Above that threshold, the heat pump has a lower energy cost, before fixed charges.

At present, household-gas measures provided under Emergency Ordinance No. 12/2026, as subsequently amended, apply until 31 March 2027. Emergency Ordinance No. 47/2026, published on 26 November, supplements the existing framework, including allocations for heat-energy producers. Separately, a Ministry of Energy proposal reported by Agerpres on the same day proposes an administratively set commodity-gas price of 120 lei/MWh for April 2027 to March 2028. This is not a final price of 0.12 lei/kWh: the explanatory note estimates about 276.66 lei/MWh including bill components, an indicative figure. In sources reviewed through 29 November, the proposal was not confirmed as adopted.

Final gas price Electricity: 1.20 lei/kWh Electricity: 1.50 lei/kWh Electricity: 1.80 lei/kWh
0.27666 lei/kWh — estimate in the proposal 3.99 4.99 5.99
0.30 lei/kWh — baseline scenario 3.68 4.60 5.52
0.42 lei/kWh — sensitivity test 2.63 3.29 3.94
Minimum SPF for equal energy costs, assuming gas efficiency of 92%. To generate savings, the effective SPF must exceed the stated value. The tariffs are assumptions and one reference point from draft legislation, not a forecast.

An expensive electricity contract can make it difficult to compete with gas, even for a well-designed system. In a home where gas is already available, compare the cost of useful energy and the investment before deciding. For a property without a gas network, a comparison with direct electric heating, LPG, wood or an expensive connection may produce a different result.

A freezing day: backup resistance heating and available electrical capacity

Assume a home needs an average thermal output of 6 kW for 24 hours, or 144 kWh of heat. At a COP of 2.85, consumption is about 50.53 kWh, costing 60.63 lei at 1.20 lei/kWh. At a COP of 2.02, consumption rises to about 71.29 kWh, costing 85.54 lei. Gas at 0.30 lei/kWh and 92% efficiency would cost about 46.96 lei for the same amount of heat. This is a mathematical test at fixed points, not an estimate of consumption on a particular day in Constanța.

An annual example is equally relevant: if 10,800 kWh of heat is supplied by the compressor at an average efficiency of 3.8, and 1,200 kWh by an electric resistance heater with approximately unit efficiency, total consumption is about 4,042 kWh. The effective SPF falls to 2.97. Using only the 3.8 ratio would underestimate the bill in this case by around 1,061 lei a year at the modelled tariff.

Thermal output and electrical power are not the same. A heat pump delivering 8 kW of heat at a COP of 2.5 draws about 3.2 kW of electricity at that point; the simultaneous start-up of a 6 kW resistance heater can take the requirement to around 9.2 kW, before other household loads. The example assumes the controller permits simultaneous operation. The designer and a licensed electrician must check the approved capacity, supply, protection devices, maximum currents and any model-specific power limits. Do not alter protective devices or disable the safety resistance heater without checking the design.

Upfront investment: what a turnkey quote should include

Autumn 2026 market benchmarks published by Sebra and EnergyHome point to widely varying budgets depending on capacity and configuration. An installed 8–12 kW air-to-water system can often cost in the region of 35,000–55,000 lei, while configurations involving rebuilt distribution systems or additional works may cost more. These are indicative commercial guides, not independent quotes for the same building.

Request in writing the capacity at the design temperature, modulation range, hydraulic equipment and controls, domestic-hot-water cylinder, electrical upgrades, installation, commissioning, any radiator works, frost protection, condensate drainage and warranty. The outdoor unit must be positioned in accordance with the manufacturer’s instructions, including those concerning noise and safety. Ask whether the quote includes new distribution pipework and whether the existing electrical connection is sufficient. For a gas boiler, the costs of connection, flue installation, approvals and inspections can be decisive.

Payback over 10 and 15 years: five scenarios for 120 m²

We assume 12,000 kWh of useful heat a year, an investment of 38,000 lei for the heat pump and 13,000 lei to replace the boiler in a home with infrastructure already available. For a home without a gas connection, we hypothetically test a total cost of 30,000 lei for the gas alternative. Operating budgets include annual provisions of 500 lei for the heat pump and 450 lei for gas, selected for modelling purposes rather than confirmed service rates. Hot water and cooling are excluded from both options.

Scenario Annual heat-pump cost Annual gas cost Annual heat-pump saving Additional-investment payback
Baseline: SPF 3.4; gas 0.30 4,735 lei 4,363 lei −372 lei Not achieved
Cheaper gas: SPF 3.4; gas 0.27666 4,735 lei 4,059 lei −677 lei Not achieved
Favourable to the heat pump: SPF 4; gas 0.42 4,100 lei 5,928 lei 1,828 lei 13.7 years
Favourable, without a gas connection (30,000 lei alternative) 4,100 lei 5,928 lei 1,828 lei 4.4 years
Existing solar PV: SPF 4; gas 0.30 3,400 lei 4,363 lei 963 lei 26 years
Assumptions: electricity at 1.20 lei/kWh; in the final scenario, a net saving of 700 lei from incremental solar self-consumption, after deducting the value of foregone exported electricity. No subsidies or future price increases assumed. Differences are calculated before rounding.
Scenario Heat pump / gas: 10 years Heat pump / gas: 15 years Difference in discounted cost over 15 years (heat pump minus gas)
Baseline 85,353 / 56,630 lei 109,029 / 78,446 lei +28,864 lei
Cheaper gas 85,353 / 53,586 lei 109,029 / 73,879 lei +32,024 lei
Favourable to the heat pump 79,000 / 72,283 lei 99,500 / 101,924 lei +6,023 lei
Favourable, without a connection 79,000 / 89,283 lei 99,500 / 118,924 lei −10,977 lei
Existing solar PV 72,000 / 56,630 lei 89,000 / 78,446 lei +15,004 lei
Total cost = investment plus constant annual expenditure in real lei. The final column discounts annual cash flows at 5%, with the investment at the initial point in time. A positive figure means the heat pump is more expensive; a negative figure means it is cheaper. Major replacements, financing, residual value, subsidies and individual fixed charges are not included.

In the favourable scenario, the heat pump may have a lower undiscounted cost after 15 years yet still be more expensive in discounted terms: the investment is paid today, while savings arise gradually. A hypothetical additional repair costing 8,000 lei at the beginning of year 11 would add about 4,911 lei to the discounted cost. A complete model must also examine possible boiler repairs, not only those of the heat pump. For an existing, working boiler, the appropriate alternative is often to keep it, rather than immediately purchase a new gas boiler; the calculations above do not quantify that case.

Solar panels and batteries: how much do they really help in winter?

In InfoBuz’s analysis of the payback of solar PV systems and batteries, a secondary climate benchmark based on PVGIS for Constanța indicates roughly 1,780 kWh produced between November and March by a 5 kWp system. If 75% of the heat pump’s annual consumption of 3,529 kWh in the average scenario is concentrated in that period, it would need about 2,647 kWh. Even before accounting for other appliances in the home, seasonal production is insufficient to cover that demand, and generation and demand do not always coincide by hour. The 75% figure is an illustrative assumption.

If an existing solar installation enables a further 1,000 kWh to be used directly by the heat pump, this avoids 1,200 lei in imports but may reduce export revenue or credits by 500 lei, at the hypothetical export value of 0.50 lei/kWh. The marginal saving is 700 lei, not 1,200 lei. If panels or batteries are installed specifically for the heat pump, the extra investment must be included in the payback calculation. A 10 kWh nominal battery with 7.6 kWh usable capacity in the previous model can supply a constant 3 kW electrical load for about 2.5 hours without solar input, before other loads and limitations. It is not a solution for seasonal self-sufficiency.

An automated system that coordinates domestic-hot-water preparation and heating with solar generation can be useful, provided it respects comfort, domestic-hot-water hygiene requirements and equipment limits. Do not raise the flow temperature excessively merely to absorb surplus generation: efficiency may fall. For local solar demand, see also Constanța solar potential.

Refrigerants in 2027: R290, R32 and which equipment remains permitted

Regulation (EU) 2024/573, Annex IV, points 8(b), 8(d) and 9(b), introduces restrictions from 1 January 2027 on placing certain self-contained heat pumps and air-to-water split systems on the market when they use fluorinated gases with a GWP of at least 150, depending on capacity and category, subject to the safety exemptions provided by the regulation. Implementing Regulation (EU) 2026/2486, adopted on 10 November, provides temporary derogations in 2027 for certain equipment, not a general postponement for all heat pumps. These restrictions do not amount to an automatic ban on using all existing appliances.

Products using R290 refrigerant (propane) have become an important option, but the refrigerant is flammable and requires compliance with specific siting and installation conditions. For example, the manufacturer’s documentation for Panasonic’s L Series describes R290 configurations with a hydraulic connection between the units. Not every product using R290 will be more efficient than every product using R32. Check the model’s compliance, the date it was placed on the market, the availability of authorised servicing and specifications for your application. Direct access to EUR-Lex pages required an anti-robot check during the research session; legislative details are taken from indexed excerpts of the official acts. For a specific purchase, check the full, updated text.

InfoBuz verdict: when is it worth investing?

A heat pump can be a very good solution in a home with controlled heat demand, low-temperature distribution and a favourable electricity tariff — especially when the alternative would require an expensive gas connection, or where cooling and energy independence have value for the owner. In a home with a working boiler, relatively inexpensive gas and radiators requiring high flow temperatures, immediate replacement can be difficult to justify financially.

Before buying, request a room-by-room heat-loss calculation, a full quote, an estimated SPF under the home’s conditions, thermal capacity in freezing weather and the cost of any adaptations. Compare three tariff scenarios and check payback including without a subsidy. Do not select equipment based on floor area, maximum COP or the capacity stated in the model name. The most efficient investment is the one that delivers the required comfort with verifiable consumption at an acceptable total cost.

InfoBuz.ro editorial analysis, researched on 29 November 2026. The simulations are original and hypothetical, not measured bills, technical designs or commercial quotes. Future tariffs and any funding are not guaranteed. Commercial benchmarks come from public guides, performance data from manufacturer documentation and the Fraunhofer study. Full access to EUR-Lex was limited by an anti-robot check. The lead image is an editorial illustration generated with artificial intelligence.

Etichete: Gas boilerHeating costsDobrogeaenergy efficiencyElectricity billHome heatingunderfloor heatingThermal insulation
Share this article
COMUNITATEA INFOBUZ

Discuția cititorilor

Ai o opinie sau o întrebare despre acest articol? Spune-ne ce crezi.

0 comentarii

Fii primul care deschide discuția.

Lasă un comentariu

Email address este vizibilă doar administratorilor și nu va fi publicată. Câmpurile marcate cu * sunt obligatorii.

Te rugăm să păstrezi un limbaj civilizat și să discuți la subiect. Comentariile spam sunt filtrate automat.